Liquid Cooling and Ventilation Garment

A Liquid Cooling Garment (LCG) is a form-fitting garment that is used to remove body heat from the wearer in environments where evaporative cooling from sweating and open air convection cooling does not work, or the wearer has a biological problem that hinders self-regulation of body temperature.

A Liquid Cooling and Ventilation Garment (LCVG) has additional crush-resistant ventilation ducts, which draw moist air from the wearer's extremities, keeping the wearer dry. In a fully enclosing suit where exhaled breathing air can enter the suit, the exhaled air is moist and can lead to an uncomfortable feeling of dampness or wetness.

While this technology is most commonly associated with space suits, it is also used in a wide range of Earth-bound applications where open-air cooling is difficult or impossible to achieve, such as fire fighting or working in a steel mill.

Contents

Technology

There are typically two parts to a liquid cooling garment:

Garment and tubing

The garment is typically a close-fitting non-stretching fabric or a tight-fitting elastic fabric, with flexible tubing sewn onto the fabric. A single-layer of fabric may be used, with the tubing either on the inside directly contacting the wearer's skin, or on the outside separated by the fabric. If two layers of fabric are used, stitched channels can be formed which enclose the tubing between the two fabric layers. Where flame resistance is needed, the garment may be constructed out of materials such as nomex.

The tubing is typically a few millimeters in diameter, and may be made out of any number of flexible plastics such as polyvinyl chloride (PVC) or silicone. Smaller diameter tubing permits a higher degree of garment flexibility, but at a cost of lower heat absorption capacity, and increased pressure needed to push liquid through the tubing.

When a large area needs to be cooled or the external environment also heats the tubing, a single long tube may not be enough because the liquid becomes saturated with heat and can not cool any further. Making the liquid much colder is not an option since it leads to uncomfortable coldness where the liquid enters the tubes. Instead, multiple parallel tubes are used to increase the volume of liquid available to absorb heat.

Skin coverage and tubing density can vary depending on the application. The garment may simply be a short-sleeved shirt, or it may be a full-body suit covering the arms and legs. Where the heat removal requirement is low, the tubing may be spaced several centimeters apart across the garment surface. Where there is a very large amount of heat to remove, the tubing can be arranged in a dense grid with no gaps between the tubes.

Heat exchanger

For portable earth bound applications, the heat exchanger for cooling the liquid can be very low-tech, consisting simply of a container for holding ice, and an electric pump to circulate water from the container through the tubing. The return water is cooled by the melting ice, and again pumped through the tubes. Regulation of flow is done by varying pump speed or using an adjustable flow valve. Ice storage can be achieved using a belt-pack, a backpack, or a duffel bag, depending on the length of time needed for the cooling system to operate between refilling the ice storage.

In situations where the wearer must stay in place inside a vehicle, heavy but long-term-operation heat exchangers can be used, such as a refrigration system to cool the liquid.

When the user's movement is partially hindered through the use of a life-support umbilical, cooling liquid can also be supplied via the umbilical.

Space applications

Astronauts commonly wear a Liquid Cooling and Ventilation Garment in order to maintain a comfortable core body temperature during extra-vehicular activity (EVA). The LCVG accomplishes this task by circulating cool water through a network of flexible tubes in direct contact with the astronaut's skin. The water draws heat away from the body, resulting in a lower core temperature. The water then returns to the Primary Life Support System (PLSS), where it is cooled in a heat exchanger before being recirculated. In an independent space suit, the heat is ultimately transferred to a thin sheet of ice (formed by a separate feed water source). Due to the extremely low pressure in space, the heated ice sublimates directly to water vapor, which is then vented away from the suit. In a dependent space suit (such as the ones used in the Gemini program or within lunar orbit on the Apollo program), the heat is carried back to a host spacecraft through an umbilical connection, where it is ultimately radiated or sublimated via the spacecraft's own thermal control system.

Because the space environment is essentially a vacuum, heat cannot be lost through heat convection, and can only be directly dissipated through thermal radiation, a much slower process. Thus, even though the environment of space can be extremely cold, excessive heat build-up is inevitable. Without an LCVG, there would be no means by which to expel this heat, and it would affect not only EVA performance, but the health of the suit occupant as well. The LCVG used with the Apollo/Skylab A7L suit could remove heat at a rate of approximately 2000 Btu/h (600 watts).[1]

The LCVG used with NASA's Extravehicular Mobility Unit is primarily constructed of spandex, with a nylon tricot liner.[2] The tubes are made of polyvinyl chloride.

Images

References

  1. ^ Carson, Maurice A.; Rouen, Michael N., Lutz, Charles C., and McBarron, James W. II. Biomedical Results of Apollo - Section VI - Chapter 6 - Extravehicular Mobility Unit. Lyndon B. Johnson Space Center. http://lsda.jsc.nasa.gov/books/apollo/S6CH6.htm. 
  2. ^ Freudenrich, Craig C.. "How Spacesuits Work". How Stuff Works. http://www.howstuffworks.com/space-suit4.htm. Retrieved 2007-01-18. 

External links